1.
The fatigue behavior of plywood specimens under shear through thickness was examined on the basis of strain energy to obtain
common empirical equations for the fatigue process and failure criterion under various loading conditions. Specimens were
cut from commercial plywood panels of 9-mm thickness. Loading conditions were set as follows: a square waveform at a loading
frequency of 0.5 Hz, a triangular waveform at 0.5 Hz, and a triangular waveform at 5.0 Hz. Peak stress applied was determined
to be 0.5, 0.7, and 0.9 of static strength, that is, stress levels of 0.5, 0.7, and 0.9. The stress-strain relationships were
measured throughout the fatigue test, and the strain energy was obtained at each loading cycle. Loading conditions apparently
affected the relationship between stress level and fatigue life. On the other hand, the relationship between mean strain energy
per cycle and fatigue life was found to be independent of loading conditions. Mean strain energy per cycle obtained as the
fatigue limit was 5.85 kJ/m3 per cycle. Assuming that the accumulation of strain energy is a fatigue indicator, the fatigue process and failure criterion
for the plywood specimens under the three loading conditions were commonly expressed by the relationship between cumulative
strain energy and loading cycles. 相似文献
2.
低速大扭矩室内动态模拟加载器及其控制系统 总被引:1,自引:0,他引:1
作者在1984年研制出我国第一台低速大扭矩加载器及其动态模拟液E伺服控制系统,本文介绍了该系统的设计、试验研究和微机控制,大量的试验研究表明,该系统性能良好。 相似文献
3.
通过汽车示波器对氧传感器的信号电压波形测试,介绍了氧传感器的标准信号电压波形、氧传感器波形分析法诊断发动机故障的一般流程及其具体应用。 相似文献
4.
通过对喷油驱动电路的波形测试来介绍波形分析的一般方法,并通过故障诊断实例来反映波形分析法诊断汽车故障的优越性。 相似文献
5.
Wang Jianping Mi Linshu Chen Gang 《保鲜与加工》1993,(6):32-37
The angular frequency and decaying constant of each copmonect for the
transient waveform in power systems were obtained by using the discrete Fourier transform; the amplitude and phase angle were calculated in the linear curve fitting method. And all of the parameters obtained above were treated in an unified optimization by using the curve fitting optimization of the least square method of general nonlinear funcrion so as to get the results of waveform analysis. Two examples are included. 相似文献
6.
7.
8.
9.
Alexander Valverde DVM DVSc DACVA Giacomo Gianotti DVM Eva Rioja DVM PhD DVSc DACVA Amanda Hathway RVT 《Journal of Veterinary Emergency and Critical Care》2011,21(4):328-334
Objective – To compare the determination of cardiac output (CO) via arterial pulse pressure waveform analysis (FloTrac/Vigileo) versus lithium dilution method. Design – Prospective study. Setting – University teaching hospital. Animals – Six adult dogs. Interventions – Dogs were instrumented for CO determinations using lithium dilution (LiDCO) and FloTrac/Vigileo methods. Direct blood pressure, heart rate, arterial blood gases, and end‐tidal isoflurane (ETIso) and CO2 concentrations were measured throughout the study while CO was manipulated with different depth of anesthesia and rapid administration of isotonic crystalloids at 60 mL/kg/h. Measurements and Main Results – Baseline CO measurements were obtained at 1.3% ETIso and were lowered by 3% ETIso. Measurements were obtained in duplicate or triplicate with LiDCO and averaged for comparison with corresponding values measured continuously with the FloTrac/Vigileo method. For 30 comparisons between methods, a mean bias of ?100 mL/kg/min and 95% limits of agreement between ?311 and +112 mL/kg/min (212 mL/kg/min) was determined. The mean (mL/kg/min) of the differences of LiDCO?Vigileo=62.0402+?0.8383 × Vigileo, and the correlation coefficient (r) between the 2 methods 0.70 for all CO determinations. The repeatability coefficients for the individual LiDCO and FloTrac/Vigileo methods were 187 and 400 mL/kg/min, respectively. Mean LiDCO and FloTrac/Vigileo values from all measurements were 145 ± 68 mL/kg/min (range, 64–354) and 244 ± 144 mL/kg/min (range, 89–624), respectively. The overall mean relative error was 48 ± 14%. Conclusion – The FloTrac/Vigileo overestimated CO values compared with LiDCO and the relative error was high, which makes this method unreliable for use in dogs. 相似文献
10.
对总RNA上样量和洗脱液温度的比较试验表明,用Promega公司生产的磁珠法试剂盒PolyAT-tract^R mRNA Isolation Systems Ⅲ Z5300纯化mRNA,每管总RNA上样量以550μg适中。将洗脱液加热至70℃,有利于提高洗脱率。550μg上样量与70℃洗脱液温度配合运用,既可保证mRNA纯化质量,充分利用总RNA样品,又可避免磁珠浪费。 相似文献